trc_px1_ac19@13 < 20201015032737-882819 > pub
  • technique: LA-ICP-MS
  • device: LA-ICP-MS (iCAP-Qs + Analyte G2 Excimer Laser system)
  • operator: Kobayashi
  • modified at 2020-10-29
  • stone: trc_px1_ac19@13
measured value uncertainty unit description
[Li] 3542.467818 103.1829345 ppb
[B] 2.557274617 0.566671347 ppm
[Al] 3484.584959 67.56566621 ppm
[Si] 23.37174603 0.154372072 %
[Ca] 2.726074555 0.412312552
[Rb] 5298.977814 194.6772381 ppb
[Sr] 1247.843888 80.49601823 ppb
[Y] 1047.586596 146.9277771 ppb
[Zr] 1602.764807 161.934547 ppb
[Nb] 80.71248379 120.7649344 ppb
[Cs] 251.1259293 16.78246247 ppb
[Ba] 1232.341946 160.5410763 ppb
[La] 129.7469832 25.84003736 ppb
[Ce] 437.6605605 31.12769719 ppb
[Pr] 66.18297079 16.57454238 ppb
[Nd] 257.4509798 99.61510406 ppb
[Sm] -20.43689002 249.2352157 ppb
[Eu] 13.37536007 46.3245091 ppb
[Gd] 133.3491057 65.17177518 ppb
[Tb] 21.38292086 23.80931703 ppb
[Dy] 216.6833158 64.25659349 ppb
[Ho] 30.47655235 16.0703315 ppb
[Er] 106.7317594 21.00564458 ppb
[Tm] 41.80535754 20.55777123 ppb
[Yb] 73.91251586 21.26784376 ppb
[Lu] 22.67322986 5.973889157 ppb
[Hf] 133.535024 41.16562834 ppb
[Pb] 13.28480172 24.97744741 ppb
[Th] 1.86e-08 4.14e-09 g/g
[U] 4.58e-09 1.58e-09 g/g
name global-id
name spots global-id