Katsura Kobayashi et al. (2004) Lithium, boron, and lead isotope systematics of glass inclusions in olivines from Hawaiian lavas: evidence for recycled components in the Hawaiian plume, Chemical Geology, 212, 143-161, doi:10.1016/j.chemgeo.2004.08.050. < 20131218125018-339370 > pub

Map on Earth or stone. Places and analyses are shown.

  • abstract:

    Lithium (Li), boron (B), and lead (Pb) isotopic compositions of glass inclusions in olivine phenocrysts from Hawaiian lavas, (Kilauea Iki, Mauna Loa, and Koolau volcano) were measured by high mass resolution ion probe to search for possible signatures of recycled materials in the Hawaiian plume. In order to measure the isotopic compositions, a set of synthetic glass standards with matrices similar to those of the target glass inclusions was prepared. Isotopic variations among these synthetic standards were produced by additions of spikes, and their isotopic compositions were determined by TIMS. Using this set of standards, correction factors for instrumental mass fractionation for Li, B, and Pb isotope measurement were determined with internal precisions of <1.2‰, <1.6‰, and <0.8% (2σ) uncertainties for Li, B, and Pb, respectively.

    Twenty-eight glass inclusions were measured after homogenization to eliminate dendritic crystals. These glass inclusions showed isotopic variations from −10.2‰ to +8.4‰ for δ7Li, from −10.5‰ to +5.2‰ for δ11B, from 0.7994 to 0.8909 for 207Pb/206Pb, and from 1.989 to 2.139 for 208Pb/206Pb, which are considerably larger than those for whole rocks. This suggests that the Hawaiian lavas are mixtures of melts derived from isotopically distinct sources, and that glass inclusions better preserve information regarding source heterogeneity than do whole rocks. In particular, significantly low δ7Li and δ11B values for the Mauna Loa and Koolau samples indicate an isotopically “light” Li and B source, perhaps containing recycled materials that experienced dehydration during subduction. The extremely low Pb isotope signature, which corresponds to HIMU, also suggests some contribution from recycled materials to the generation of the Hawaiian magma. Our results suggest that recycled materials, which experienced near-surface alteration and then dehydration during subduction, played an important role in creating geochemical heterogeneity in the Hawaiian lavas.

  • doi: 10.1016/j.chemgeo.2004.08.050
  • modified at 2020-07-30
1: HW7-3_7-1_melt inclusion 2: HW7-3_11-1_melt inclusion 3: HW7-3_23-1_melt inclusion 4: HW7-3_26-1_melt inclusion 5: HW7-3_28-1_melt inclusion 6: HW7-3_30-2 7: HW7-3_38-1_melt inclusion 8: HW30_2-1_melt inclusion 9: HW30_3-2_melt inclusion 10: HW30_6-1_melt inclusion 11: HW30_7-2 12: HW30_10-1_melt inclusion 13: HW30_13-1_melt inclusion 14: HW30_18-2_melt inclusion 15: K89-6_12-1_melt inclusion 16: K89-6_14-1_melt inclusion 17: K89-6_17-1_melt inclusion 18: K89-6_20-1_melt inclusion 19: K89-6_22-2_melt inclusion 20: K89-6_22-3_melt inclusion 21: WAF-39_1-1_melt inclusion 22: WAF-39_4-1_melt inclusion 23: WAF-39_5-1_melt inclusion 24: WAF-39_3-1_melt inclusion 25: S500-5B_7-1_melt inclusion 26: S500-5B_22-1_melt inclusion 27: S500-5B_24-1_melt inclusion 28: S500-5B_37-1_melt inclusion


(a) SIMS on SIMS Cameca ims-1270
(b) SIMS on SIMS Cameca ims-5f
1: HW7-3_7-1_melt inclusion 2: HW7-3_11-1_melt inclusion 3: HW7-3_23-1_melt inclusion 4: HW7-3_26-1_melt inclusion 5: HW7-3_28-1_melt inclusion 6: HW7-3_30-2 7: HW7-3_38-1_melt inclusion 8: HW30_2-1_melt inclusion 9: HW30_3-2_melt inclusion 10: HW30_6-1_melt inclusion 11: HW30_7-2 12: HW30_10-1_melt inclusion 13: HW30_13-1_melt inclusion 14: HW30_18-2_melt inclusion 15: K89-6_12-1_melt inclusion 16: K89-6_14-1_melt inclusion 17: K89-6_17-1_melt inclusion 18: K89-6_20-1_melt inclusion 19: K89-6_22-2_melt inclusion 20: K89-6_22-3_melt inclusion 21: WAF-39_1-1_melt inclusion 22: WAF-39_4-1_melt inclusion 23: WAF-39_5-1_melt inclusion 24: WAF-39_3-1_melt inclusion 25: S500-5B_7-1_melt inclusion 26: S500-5B_22-1_melt inclusion 27: S500-5B_24-1_melt inclusion 28: S500-5B_37-1_melt inclusion


(a) SEM-EDX on SEM-EDX 3100H with HORIBA EMAX
(b) SIMS on SIMS Cameca ims-5f
1: SA86-0NA 2: SA86-1NA 3: SA86-2NA 4: SA86-3NA 5: SA86-4NB 6: MG90A10 7: MG76A24 8: FMSA Glass STD 9: Koolau 496-6E-1


(a) SIMS on SIMS Cameca ims-1270
1: SA86-0NA 2: SA86-1NA 3: SA86-2NA 4: SA86-3NA 5: SA86-4NB 6: MG90A10 7: MG76A24 8: FMSA Glass STD 9: Koolau 496-6E-1


(a) TIMS on TIMS Finnigan MAT261, MAT262 and Triton TI
1: HW7-3 2: HW30 5: S500-5B


(a) XRF procedures of Takei (2002) on XRF PANalytical PW2400
(b) Q-ICP-MS_procedures of Makishima and Nakamura (1997, 1999, 2006) on ICPMS Yokogawa PMS2000/Agilent 7500cs
(c) B_procedures of Makishima et al. (1997) on ICPMS Yokogawa PMS2000/Agilent 7500cs
(d) TIMS on TIMS Finnigan MAT261, MAT262 and Triton TI
(e) Pb isotopes_procedures of Kuritani and Nakamura (2002, 2003) on TIMS Finnigan MAT261, MAT262 and Triton TI
Img 5159@60f47f08471307856d4014e thumb SA86-4NB < 20120130094809-685-892 >pub
  • physical-form: on mount
  • status: (unknown)
  • description: homogenized glass of (Li-B) spike-doped powder
  • modified at 2019-07-11
Img 5160@8d129125a6dd679e92148db thumb SA86-1NA < 20120130094844-839-325 >pub
  • physical-form: on mount
  • status: (unknown)
  • description: homogenized glass of (Li-B) spike-doped powder
  • modified at 2019-07-11
Img 5161@9e0d60ed514d3aeeb97d2bd thumb SA86-3NA < 20120130094854-372-117 >pub
  • physical-form: on mount
  • status: (unknown)
  • description: homogenized glass of (Li-B) spike-doped powder Leave bench 1270 <20110331181325-307-312> and enter bench 1270 <20110331181325-307-312> on 2015-08-02.
  • modified at 2019-07-11
Img 5162@456002e76e69073561ce288 thumb SA86-2NA < 20120130094902-978-646 >pub
  • physical-form: on mount
  • status: (unknown)
  • description: homogenized glass of (Li-B) spike-doped powder
  • modified at 2019-07-11
Img 5158@f52c6ad098016d44ccdb15a thumb SA86-0NA < 20120130094922-387-258 >pub
  • physical-form: on mount
  • status: (unknown)
  • description: homogenized glass of (Li-B) spike-doped powder
  • modified at 2019-07-11
Img 5501@a481e5979dc5b8e01fce0a9 thumb FMSA Glass STD < 20120308094933-178-199 >pub
  • classification: synthetic:glass
  • physical-form: on mount
  • status: (unknown)
  • modified at 2019-07-11
Img 5506@5360f1f10307333f28d6ba1 thumb MG90A10 < 20120309094329-217-360 >pub
  • physical-form: grain
  • status: (unknown)
  • modified at 2019-07-11
Img 5508@3e1d3ae45dae5de1621162a thumb Koolau 496-6E-1 < 20120309094349-100-152 >pub
  • physical-form: grain
  • status: (unknown)
  • modified at 2019-07-11
Img 5536@5c147f8ae0c8b725a79c73a thumb MG76A24 < 20120314095913-744-452 >pub
  • physical-form: grain
  • status: (unknown)
  • modified at 2019-07-11
Tixhr 1647351591 thumb S500-5B < 20190517105622-684076 >pub
  • IGSN: IEDRM00IF
  • place: N21°50′59.0″, W157°45′33.0″ more
  • classification: volcanic:basaltic
  • physical-form: aliquot
  • quantity (g): 9.88
  • description: Lowermost Makapuu stage: submarine lavas, Oahu North-a; picrite lava
  • modified at 2020-04-06
Tixhr1381820379 thumb HW7-3 < 20190703105652-638661 >pub
  • IGSN: IEDRM00L0
  • place: N19°24′54.0″, W155°15′1.0″ more
  • classification: volcanic:basaltic
  • physical-form: hand specimen
  • quantity (kg): 0.28
  • age (a): 62.0 (0.0)
  • description: Big Island, Kilauea-lki lava
  • modified at 2020-04-06
Tixhr1999651971 thumb HW30 < 20190704091454-522495 >pub
  • IGSN: IEDRM00LA
  • place: N19°32′30.0″, W155°34′1.0″ more
  • classification: volcanic:basaltic
  • physical-form: hand specimen
  • quantity (kg): 0.385
  • description: Big Island, Mauna Loa, pre-historic Northeast Rift Zone lava
  • modified at 2019-07-05
name box-type global-id
binder of Lithium, boron, and lead isotope systematics of glass inclusions in olivines from Hawaiian lavas: evidence for recycled components in the Hawaiian plume pub container 20190531104755-289254
name latitude longitude global-id
locality of S500-5B pub 21.8497 N 157.7592 W 20190521145057-063450
Kilauea pub 19.4150 N 155.2503 W 20190705134948-904374
Mauna Loa pub 19.5417 N 155.5669 W 20190705152112-016437
name device size global-id
SA86-4NB pub TIMS Finnigan MAT261, MAT262 and Triton TI 4 20190531114019-328198
SA86-4NB pub SIMS Cameca ims-1270 2 20190531114005-896123
SA86-1NA pub SIMS Cameca ims-1270 2 20190531114005-596996
SA86-1NA pub TIMS Finnigan MAT261, MAT262 and Triton TI 4 20190531114018-595203
SA86-3NA pub TIMS Finnigan MAT261, MAT262 and Triton TI 4 20190531114018-956734
SA86-3NA pub SIMS Cameca ims-1270 2 20190531114005-050726
SA86-2NA pub SIMS Cameca ims-1270 2 20190531114005-133114
SA86-2NA pub TIMS Finnigan MAT261, MAT262 and Triton TI 4 20190531114018-677607
SA86-0NA pub SIMS Cameca ims-1270 2 20190531114004-004025
SA86-0NA pub TIMS Finnigan MAT261, MAT262 and Triton TI 4 20190531114017-650992
FMSA Glass STD pub SIMS Cameca ims-1270 2 20190531114005-687835
FMSA Glass STD pub TIMS Finnigan MAT261, MAT262 and Triton TI 2 20190531114019-706420
MG90A10 pub TIMS Finnigan MAT261, MAT262 and Triton TI 2 20190531114019-018193
MG90A10 pub SIMS Cameca ims-1270 2 20190531114005-844223
Koolau 496-6E-1 pub SIMS Cameca ims-1270 2 20190531114005-024066
Koolau 496-6E-1 pub TIMS Finnigan MAT261, MAT262 and Triton TI 2 20190531114019-610218
MG76A24 pub TIMS Finnigan MAT261, MAT262 and Triton TI 2 20190531114019-335890
MG76A24 pub SIMS Cameca ims-1270 2 20190531114005-630344
S500-5B pub ICPMS Yokogawa PMS2000/Agilent 7500cs 28 20190521114921-813801
S500-5B pub TIMS Finnigan MAT261, MAT262 and Triton TI 1 20190521120004-768315
S500-5B_Pb2002 pub TIMS Finnigan MAT261, MAT262 and Triton TI 3 20190521120651-039912
S500-5B pub TIMS Finnigan MAT261, MAT262 and Triton TI 2 20190521120307-327776
S500-5B pub ICPMS Yokogawa PMS2000/Agilent 7500cs 1 20190521100452-618247
S500-5B pub TIMS Thermo-Fisher MAT261 2 20190521101550-953604
S500-5B pub MC-ICP-MS Finnigan, Neptune 2 20190521144803-462160
S500-5B pub 1 20190521103319-764275
S500-5B_Pb2008 pub TIMS Finnigan MAT261, MAT262 and Triton TI 5 20190521160244-959239
S500-5B pub TIMS Finnigan MAT261, MAT262 and Triton TI 2 20190531140148-665046
S500-5B pub XRF PANalytical PW2400 15 20190625111414-184557
S500-5B pub 3 20190625111228-473375
S500-5B_37-1 pub SEM-EDX 3100H with HORIBA EMAX 9 20190531140954-942079
S500-5B_24-1 pub SEM-EDX 3100H with HORIBA EMAX 9 20190531140954-901544
S500-5B_22-1 pub SEM-EDX 3100H with HORIBA EMAX 9 20190531140953-546084
S500-5B_7-1 pub SEM-EDX 3100H with HORIBA EMAX 9 20190531140953-426544
WAF-39_3-1 pub SEM-EDX 3100H with HORIBA EMAX 9 20190531140953-196783
WAF-39_5-1 pub SEM-EDX 3100H with HORIBA EMAX 9 20190531140953-463733
WAF-39_1-1 pub SEM-EDX 3100H with HORIBA EMAX 9 20190531140952-812142
K89-6_22-3 pub SEM-EDX 3100H with HORIBA EMAX 9 20190531140952-093037
K89-6_22-2 pub SEM-EDX 3100H with HORIBA EMAX 9 20190531140952-683711
K89-6_17-1 pub SEM-EDX 3100H with HORIBA EMAX 9 20190531140951-868030
K89-6_14-1 pub SEM-EDX 3100H with HORIBA EMAX 9 20190531140951-255609
K89-6_12-1 pub SEM-EDX 3100H with HORIBA EMAX 9 20190531140951-820566
HW30_10-1 pub SEM-EDX 3100H with HORIBA EMAX 9 20190531140950-499663
HW30_7-2 pub SIMS Cameca ims-5f 9 20190531140950-079912
HW30_6-1 pub SEM-EDX 3100H with HORIBA EMAX 9 20190531140950-573878
HW7-3_28-1 pub SEM-EDX 3100H with HORIBA EMAX 9 20190531140948-785646
HW7-3_26-1 pub SEM-EDX 3100H with HORIBA EMAX 9 20190531140948-235962
HW7-3_23-1 pub SEM-EDX 3100H with HORIBA EMAX 9 20190531140948-738053
HW7-3_11-1 pub SEM-EDX 3100H with HORIBA EMAX 9 20190531140947-787477
HW7-3_7-1 pub SEM-EDX 3100H with HORIBA EMAX 9 20190531140947-275211
WAF-39 pub ICPMS Yokogawa PMS2000/Agilent 7500cs 28 20190521114915-319751
K89-6 pub ICPMS Yokogawa PMS2000/Agilent 7500cs 28 20190521114919-489433
HW30 pub TIMS Finnigan MAT261, MAT262 and Triton TI 5 20190520101505-029733
HW7-3 pub TIMS Finnigan MAT261, MAT262 and Triton TI 5 20190520101505-466783
WAF-39_4-1 pub SEM-EDX 3100H with HORIBA EMAX 9 20190531140952-265312
HW7-3 pub MC-ICP-MS Finnigan, Neptune 2 20190521144804-257771
K89-6_20-1 pub SEM-EDX 3100H with HORIBA EMAX 9 20190531140952-413675
HW30_18-2 pub SEM-EDX 3100H with HORIBA EMAX 9 20190531140951-102472
HW30_13-1 pub SEM-EDX 3100H with HORIBA EMAX 9 20190531140950-317329
HW30_3-2 pub SEM-EDX 3100H with HORIBA EMAX 9 20190531140949-178700
HW30_2-1 pub SEM-EDX 3100H with HORIBA EMAX 9 20190531140949-768487
HW7-3_38-1 pub SEM-EDX 3100H with HORIBA EMAX 9 20190531140949-155428
HW7-3_30-2 pub SIMS Cameca ims-5f 9 20190531140948-731968
WAF-39 pub TIMS Finnigan MAT261, MAT262 and Triton TI 1 20190521120004-299790
K89-6 pub TIMS Finnigan MAT261, MAT262 and Triton TI 1 20190521120004-847051
HW30 pub MC-ICP-MS Finnigan, Neptune 2 20190521144804-929134
K89-6_Pb2002 pub TIMS Finnigan MAT261, MAT262 and Triton TI 3 20190521120651-719080
WAF-39_Pb2002 pub TIMS Finnigan MAT261, MAT262 and Triton TI 3 20190521120650-456294
HW7-3 pub TIMS Finnigan MAT261, MAT262 and Triton TI 1 20190520101836-041201
HW30 pub TIMS Finnigan MAT261, MAT262 and Triton TI 1 20190520101836-223679
K89-6 pub TIMS Finnigan MAT261, MAT262 and Triton TI 2 20190521120307-349006
WAF-39 pub TIMS Finnigan MAT261, MAT262 and Triton TI 2 20190521120307-409104
HW7-3 pub TIMS Finnigan MAT261, MAT262 and Triton TI 2 20190520102113-839307
HW30 pub TIMS Finnigan MAT261, MAT262 and Triton TI 2 20190520102113-005675
HW30_leached pub ICPMS Yokogawa PMS2000/Agilent 7500cs 1 20190521091755-069161
K89-6_Pb2008 pub TIMS Finnigan MAT261, MAT262 and Triton TI 5 20190521160243-235770
WAF-39 pub ICPMS Yokogawa PMS2000/Agilent 7500cs 1 20190521100452-947192
HW7-3 pub ICPMS Yokogawa PMS2000/Agilent 7500cs 1 20190521091754-222020
S500-5B_leached pub ICPMS Yokogawa PMS2000/Agilent 7500cs 1 20190521100452-476212
WAF-39_leached pub ICPMS Yokogawa PMS2000/Agilent 7500cs 1 20190521100452-512192
K89-6 pub ICPMS Yokogawa PMS2000/Agilent 7500cs 1 20190521100451-821995
HW30 pub ICPMS Yokogawa PMS2000/Agilent 7500cs 1 20190521091755-109667
HW7-3_leached pub ICPMS Yokogawa PMS2000/Agilent 7500cs 1 20190521091754-908909
K89-6_leached pub ICPMS Yokogawa PMS2000/Agilent 7500cs 1 20190521100451-911654
HW30 pub XRF PANalytical PW2400 14 20190516152449-006719
WAF-39 pub TIMS Thermo-Fisher MAT261 2 20190521101551-715383
HW7-3 pub XRF PANalytical PW2400 15 20190516152447-372923
WAF-39_leached pub TIMS Thermo-Fisher MAT261 1 20190521101551-070472
K89-6 pub TIMS Thermo-Fisher MAT261 2 20190521101550-932309
S500-5B_leached pub TIMS Thermo-Fisher MAT261 1 20190521101550-329451
HW30 pub TIMS Thermo-Fisher MAT261 2 20190521101549-291661
HW7-3 pub TIMS Thermo-Fisher MAT261 2 20190521101548-079477
K89-6_leached pub TIMS Thermo-Fisher MAT261 1 20190521101550-002605
WAF-39 pub MC-ICP-MS Finnigan, Neptune 2 20190521144802-864966
HW30_leached pub TIMS Thermo-Fisher MAT261 1 20190521101549-747738
HW7-3_leached pub TIMS Thermo-Fisher MAT261 1 20190521101549-415107
K89-6 pub MC-ICP-MS Finnigan, Neptune 2 20190521144803-909107
HW30 pub 2 20190516153545-688535
HW7-3 pub 2 20190516153545-644193
WAF-39 pub 1 20190521103319-120700
K89-6 pub 1 20190521103319-821101
HW7-3 pub ICPMS Yokogawa PMS2000/Agilent 7500cs 4 20190516155621-669925
HW30 pub ICPMS Yokogawa PMS2000/Agilent 7500cs 4 20190516155621-782477
HW7-3 pub 1 20190521103318-305608
HW30 pub 1 20190521103318-291951
WAF-39_Pb2008 pub TIMS Finnigan MAT261, MAT262 and Triton TI 5 20190521160243-896360
HW7-3 pub ICPMS Yokogawa PMS2000/Agilent 7500cs 23 20190516155515-956443
HW30 pub ICPMS Yokogawa PMS2000/Agilent 7500cs 23 20190516155516-733011
WAF-39 pub TIMS Finnigan MAT261, MAT262 and Triton TI 2 20190531140148-025943
K89-6 pub TIMS Finnigan MAT261, MAT262 and Triton TI 2 20190531140147-116098
HW7-3 pub TIMS Finnigan MAT261, MAT262 and Triton TI 2 20190531140147-573669
HW30 pub TIMS Finnigan MAT261, MAT262 and Triton TI 2 20190531140147-508497
HW7-3_38-1 pub SIMS Cameca ims-5f 2 20190531143917-582491
HW7-3_7-1 pub SIMS Cameca ims-5f 2 20190531143916-584604
HW7-3_11-1 pub SIMS Cameca ims-5f 2 20190531143916-806819
HW7-3_23-1 pub SIMS Cameca ims-5f 2 20190531143916-017135
HW7-3_26-1 pub SIMS Cameca ims-5f 2 20190531143917-788420
HW7-3_28-1 pub SIMS Cameca ims-5f 2 20190531143917-643821
HW7-3_30-2 pub SIMS Cameca ims-5f 2 20190531143917-180654
HW7-3_7-1 pub SIMS Cameca ims-1270 4 20190531143936-432163
HW7-3_11-1 pub SIMS Cameca ims-1270 4 20190531143936-975031
HW7-3_23-1 pub SIMS Cameca ims-1270 4 20190531143936-571556
HW7-3_26-1 pub SIMS Cameca ims-1270 4 20190531143936-121593
HW7-3_28-1 pub SIMS Cameca ims-1270 4 20190531143936-141665
HW7-3_30-2 pub SIMS Cameca ims-1270 2 20190531143937-102223
HW7-3_38-1 pub SIMS Cameca ims-1270 4 20190531143937-440375
HW30_2-1 pub SIMS Cameca ims-5f 2 20190531143917-573936
HW30_10-1 pub SIMS Cameca ims-5f 2 20190531143917-599172
HW30_3-2 pub SIMS Cameca ims-5f 2 20190531143917-376735
HW30_6-1 pub SIMS Cameca ims-5f 2 20190531143917-595744
HW30_7-2 pub SIMS Cameca ims-5f 2 20190531143917-949887
HW30_13-1 pub SIMS Cameca ims-5f 2 20190531143917-942869
HW30_18-2 pub SIMS Cameca ims-5f 2 20190531143917-818502
HW30_2-1 pub SIMS Cameca ims-1270 4 20190531143937-344248
HW30_3-2 pub SIMS Cameca ims-1270 4 20190531143937-937668
HW30_6-1 pub SIMS Cameca ims-1270 4 20190531143937-867321
HW30_7-2 pub SIMS Cameca ims-1270 2 20190531143937-588133
HW30_10-1 pub SIMS Cameca ims-1270 4 20190531143937-136853
HW30_13-1 pub SIMS Cameca ims-1270 4 20190531143937-899723
HW30_18-2 pub SIMS Cameca ims-1270 4 20190531143937-745276
K89-6_12-1 pub SIMS Cameca ims-5f 2 20190531143918-632710
K89-6_17-1 pub SIMS Cameca ims-5f 2 20190531143918-820991
K89-6_14-1 pub SIMS Cameca ims-5f 2 20190531143918-858900
K89-6_20-1 pub SIMS Cameca ims-5f 2 20190531143918-891754
K89-6_22-2 pub SIMS Cameca ims-5f 2 20190531143918-481324
K89-6_22-3 pub SIMS Cameca ims-5f 2 20190531143918-499636
K89-6_17-1 pub SIMS Cameca ims-1270 4 20190531143938-556095
K89-6_20-1 pub SIMS Cameca ims-1270 4 20190531143938-221192
K89-6_22-2 pub SIMS Cameca ims-1270 4 20190531143938-392468
K89-6_22-3 pub SIMS Cameca ims-1270 4 20190531143938-101848
K89-6_12-1 pub SIMS Cameca ims-1270 4 20190531143937-562497
K89-6_14-1 pub SIMS Cameca ims-1270 4 20190531143938-795954
WAF-39_1-1 pub SIMS Cameca ims-5f 2 20190531143918-096566
WAF-39_4-1 pub SIMS Cameca ims-5f 2 20190531143918-152773
WAF-39_5-1 pub SIMS Cameca ims-5f 2 20190531143918-811533
WAF-39_3-1 pub SIMS Cameca ims-5f 2 20190531143918-367775
WAF-39_1-1 pub SIMS Cameca ims-1270 4 20190531143938-300853
WAF-39_4-1 pub SIMS Cameca ims-1270 4 20190531143938-705867
WAF-39_5-1 pub SIMS Cameca ims-1270 4 20190531143938-246843
WAF-39_3-1 pub SIMS Cameca ims-1270 4 20190531143938-269134
S500-5B_7-1 pub SIMS Cameca ims-5f 2 20190531143918-876202
S500-5B_22-1 pub SIMS Cameca ims-5f 2 20190531143918-194877
S500-5B_24-1 pub SIMS Cameca ims-5f 2 20190531143918-811269
S500-5B_37-1 pub SIMS Cameca ims-5f 2 20190531143918-344103
S500-5B_7-1 pub SIMS Cameca ims-1270 4 20190531143938-468410
S500-5B_22-1 pub SIMS Cameca ims-1270 4 20190531143939-864954
S500-5B_24-1 pub SIMS Cameca ims-1270 4 20190531143939-564760
S500-5B_37-1 pub SIMS Cameca ims-1270 4 20190531143939-983695
K89-6 pub XRF PANalytical PW2400 15 20190625111413-379480
WAF-39 pub XRF PANalytical PW2400 15 20190625111411-820789
K89-6 pub 3 20190625111228-333067
WAF-39 pub 3 20190625111227-778930
S500-5B_leachate pub TIMS Thermo-Fisher MAT261 1 20190625142026-589941
WAF-39_leachate pub TIMS Thermo-Fisher MAT261 1 20190625142026-516772
K8906_leachate pub TIMS Thermo-Fisher MAT261 1 20190625142026-625101
name spots global-id
caption ID rowname stone
Table 4. Analytical results of Li-B-Pb isotope compositions and Li-B concentrations of glass inclusions from Hawaiian volcanics pub 20190531143232-896847 glass inclusions_isotope by TIMS (Kobayashi et al., 2004) 28
Table 3. Analytical results of major element compositions of glass inclusions from Hawaiian volcanics pub 20190531141427-506170 major_inclusions (Kobayashi et al, 2004) 28
Table 1. Representative result of the ion probe analysis on synthetic glass standads pub 20190531113050-965139 glass std_isotope by SIMS(Kobayashi et al., 2004) 9
Table 1. Reference isotope compositions of synthetic glass standards pub 20190531112953-859468 glass std_isotope by TIMS(Kobayashi et al., 2004) 9
Table 2. Whole-rock geochemical characteristics of the examined samples from Hawaii pub 20190531134928-263563 major-trace-isotope (Kobayashi et al., 2004) 3
manual
  • name
  • Katsura Kobayashi
  • Ryoji Tanaka
  • Takuya Moriguti
  • Kenji Shimizu
  • Eizo Nakamura